Adson Forceps, 1X2 Teeth, With Platform 10mm, 1mm Tip, 12cm (4-3/4″)
€13.50
- 1×2 teeth and a fine 1mm tip for secure handling of skin and delicate tissue
- 10mm tying platform for instrument tying of fine sutures
- German stainless steel (AISI 410), 12cm (4-3/4″)
- Reusable, supplied non-sterile, 1-year replacement warranty
In stock (can be backordered)
- Premium Quality
- Secure Payments
- Satisfaction Guarantee
- Worldwide Shipping
- After Sale Support
Description
The SPIRAL Adson Forceps with 1×2 teeth and tying platform combine two tasks in one instrument: secure tissue handling and fine suture tying. The 1×2 teeth at the 1mm tip hold skin edges and delicate tissue with minimal slippage, while the 10mm tying platform just behind the tip gives a flat, smooth surface for tying fine sutures.
Forged from German stainless steel (AISI 410), the forceps are tensioned for a light, responsive feel, and the serrated grip area keeps control steady through long procedures. Each pair is hand-finished and checked for tip alignment in our own facility in Sialkot.
Overall length 12cm (4-3/4″).
Made under our ISO 13485-certified quality system. Reusable and supplied non-sterile: clean and sterilize before use. Covered by SPIRAL’s 1-year replacement warranty against manufacturing defects and corrosion.
Additional information
| Weight | 0.060 kg |
|---|---|
| Manufacturer | Spiral Surgical Co. |
| Material | German Stainless Steel (AISI 410) |
| Sterility Condition | |
| Grade | Premium-Operating Room |
| Usage | Reusable |
| 1 Year Replacement Warranty | Warranty Included (360 Days) |
Use SPIRAL Surgical Co. instruments only for their intended purpose. Before each use, inspect for damage, wear, corrosion, and proper function. Do not use damaged or defective instruments.
Cleaning
Remove visible soil using a suitable cleaning solution and a soft brush, paying attention to joints and channels. Rinse thoroughly and repeat cleaning if residue remains. Follow the cleaning procedure in the complete IFUs.
Disinfection
Follow the IFU disinfection procedure and the disinfectant manufacturer’s instructions for concentration, contact time, and rinsing. Disinfection does not replace required sterilization.
Sterilization
Follow the steam sterilization procedure in the complete IFUs. Process hinged instruments fully open, and check packaging integrity and sterilization indicators after processing.
Storage
Store in a dry area protected from direct sunlight and moisture. Use protective caps where needed, and keep sterilized instruments in intact sterile-barrier packaging until use.























Reviews
There are no reviews yet