Joseph Skin Hook, 16cm, Double Prong, Sharp
$10.00
- Two sharp prongs for a stable, low-trauma hold on skin edges
- Widths of 2.0mm, 5.0mm, 7.0mm and 10.0mm
- German stainless steel (AISI 410); 16cm with a balanced handle
- Reusable, supplied non-sterile, 1-year replacement warranty
- Premium Quality
- Secure Payments
- Satisfaction Guarantee
- Worldwide Shipping
- After Sale Support
Description
The SPIRAL Joseph Skin Hook with double sharp prongs is a classic for retracting skin and soft-tissue flaps in rhinoplasty, facial plastic surgery and other fine procedures. The two prongs spread the load across the tissue edge, giving a steadier hold than a single prong with less tissue trauma.
Choose from four prong widths (2.0mm, 5.0mm, 7.0mm or 10.0mm) to match the size of the incision. The hook is made from German stainless steel (AISI 410) and hand-finished in our own facility in Sialkot. The prongs are sharpened and aligned so they enter tissue cleanly.
Overall length 16cm.
Made under our ISO 13485-certified quality system. Reusable and supplied non-sterile: clean and sterilize before use. Covered by SPIRAL’s 1-year replacement warranty against manufacturing defects and corrosion.
Additional information
| Weight | 0.050 kg |
|---|---|
| Manufacturer | Spiral Surgical Co. |
| Material | German Stainless Steel (AISI 410) |
| Sterility Condition | |
| Width | 10.0mm, 2.0mm, 5.0mm, 7.0mm |
| Grade | Premium-Operating Room |
| Usage | Reusable |
| 1 Year Replacement Warranty | Select a product option to view its warranty coverage. |
Use SPIRAL Surgical Co. instruments only for their intended purpose. Before each use, inspect for damage, wear, corrosion, and proper function. Do not use damaged or defective instruments.
Cleaning
Remove visible soil using a suitable cleaning solution and a soft brush, paying attention to joints and channels. Rinse thoroughly and repeat cleaning if residue remains. Follow the cleaning procedure in the complete IFUs.
Disinfection
Follow the IFU disinfection procedure and the disinfectant manufacturer’s instructions for concentration, contact time, and rinsing. Disinfection does not replace required sterilization.
Sterilization
Follow the steam sterilization procedure in the complete IFUs. Process hinged instruments fully open, and check packaging integrity and sterilization indicators after processing.
Storage
Store in a dry area protected from direct sunlight and moisture. Use protective caps where needed, and keep sterilized instruments in intact sterile-barrier packaging until use.