Trepsat Spoon Tip Separator/Dissector Scissors, Straight – 20cm, Black-Line
$75.00
- Spoon-shaped tips for separating and dissecting tissue planes in facial surgery
- Black-Line: our finest Supercut grade with tungsten carbide inserts
- Razor-sharp blades; black ceramic coating on the whole instrument
- German stainless steel (AISI 420), 20cm · reusable, 1-year warranty
In stock (can be backordered)
- Premium Quality
- Secure Payments
- Satisfaction Guarantee
- Worldwide Shipping
- After Sale Support
Description
The SPIRAL Trepsat Spoon Tip Separator/Dissector Scissors are 20cm straight scissors for facelift and facial plastic surgery. The spoon-shaped tips let you separate tissue planes bluntly and then cut with the same instrument, keeping dissection smooth and controlled.
Black-Line is the finest grade of our Supercut scissors. Each pair has razor-sharp cutting blades in the Supercut design (one micro-serrated blade holds tissue while the knife-edge blade cuts cleanly), with tungsten carbide brazed onto the blade edges for strength and longer-lasting sharpness. The whole instrument is finished in a black ceramic coating that sets Black-Line apart on the tray.
Made from German stainless steel (AISI 420), each pair is ground, set and hand-finished in our own facility in Sialkot.
Made under our ISO 13485-certified quality system. Reusable and supplied non-sterile: clean and sterilize before use. Covered by SPIRAL’s 1-year replacement warranty against manufacturing defects and corrosion.
Additional information
| Weight | 0.1 kg |
|---|---|
| Manufacturer | Spiral Surgical Co. |
| Material | German Stainless Steel (AISI 420) |
| Sterility Condition | |
| Usage | Reusable |
| 1 Year Replacement Warranty | Warranty Included (360 Days) |
Use SPIRAL Surgical Co. instruments only for their intended purpose. Before each use, inspect for damage, wear, corrosion, and proper function. Do not use damaged or defective instruments.
Cleaning
Remove visible soil using a suitable cleaning solution and a soft brush, paying attention to joints and channels. Rinse thoroughly and repeat cleaning if residue remains. Follow the cleaning procedure in the complete IFUs.
Disinfection
Follow the IFU disinfection procedure and the disinfectant manufacturer’s instructions for concentration, contact time, and rinsing. Disinfection does not replace required sterilization.
Sterilization
Follow the steam sterilization procedure in the complete IFUs. Process hinged instruments fully open, and check packaging integrity and sterilization indicators after processing.
Storage
Store in a dry area protected from direct sunlight and moisture. Use protective caps where needed, and keep sterilized instruments in intact sterile-barrier packaging until use.